APC AP7901B power distribution unit (PDU) 1U Black 8 AC outlet(s) - (AP7901B) only $745.48

MFG Part #: AP7901B | WEB ID: 1594114
APC AP7901B, Switched, 1U, Black, cUL, CSA, FCC 15 A, ICES-003, UL 60950, UL, 8 AC outlet(s), NEMA 5–20R
Switched, 1U, 2400VA, 20A, 120V, 50/60 Hz, 8x NEMA 5-20R, NEMA L5-20P, 445 x 108 x 44 mm, 2270 g

Usually Ships: 2 to 3 weeks

Regular Price: $798.48

Sale Price $745.48

Sign up for price alert
SCHNEIDER ELECTRIC

Warehouse Availability

**Up to 15 minute delay for inventory

Backorder this product now and you will not be invoiced until it ships!

We get to work the minute your order is received, our average turn around time is 2 to 3 weeks.

Once received, your product is shipped to you via next business day delivery to all major cities in Canada

Cancel your order at any time before it ships - no strings attached


Customer Testimonials
Rating:
Lowest Price, Very Fast delivery and everything is working well so far.
Chris D, Okotoks, Alberta

Product Description

Details
APC AP7901B. PDU types: Switched, Rack capacity: 1U, Product colour: Black. AC outlets quantity: 8 AC outlet(s), AC outlet types: NEMA 5–20R, Input connection type: NEMA L5-20P. Monitoring: Current, Outlet control: Recycle,Turn off. Cable length: 3.66 m. Nominal input voltage: 120 V, Maximum current: 20 A, AC input frequency: 50/60 Hz
Availability

Network Management Capabilities
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

Remote Individual Outlet Control
Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).

Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)

Local Current Monitoring Display
The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)

Power Delays
Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.

Load indicator LED
Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.

Flash Upgradeable
Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)

Integrates with StruxureWare Data Center Expert
An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network

Marketing Features

Remote Individual Outlet Control
Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).

Remote Management Capabilities
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.

Power Delays
Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.

Local Current Monitoring Display
The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.

Agility

Single input power source
Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.

Rack-Mountable
Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.

Wide range of input and output connections
Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.
2 years repair or replace

Technical Information

Technical Information

Ports & interfaces

AC outlets quantity8 AC outlet(s)
AC outlet typesNEMA 5–20R
Input connection typeNEMA L5-20P

Weight & dimensions

Dimensions (WxDxH)17.52 x 4.25 x 1.73 "
Weight1.03 lbs
Package dimensions (WxDxH)18.5 x 13.5 x 2.76 "
Package weight1.56 lbs

Power

Nominal input voltage120 V
Maximum current20 A
AC input frequency50/60 Hz
Nominal output voltage120 V
Load capacity2400 VA
Maximum input current per phase20 A
Maximum total current draw per phase16 A

Operational conditions

Operating temperature (T-T)0 - 45 °C
Storage temperature (T-T)-25 - 65 °C
Operating relative humidity (H-H)0 - 95 %
Storage relative humidity (H-H)0 - 95 %
Operating altitude0 - 3000 m
Non-operating altitude0 - 15000 m

Management features

MonitoringCurrent
Outlet controlRecycle,Turn off

Ergonomics

Cable length3.66 m

Design

PDU typesSwitched
Rack capacity1U
Product colourBlack
RoHS complianceY
CertificationcUL, CSA, FCC 15 A, ICES-003, UL 60950, UL

Reviews

Contact Us

Have a question about this product or need assistance? We would love to hear from you!

Please fill in the form bellow and a sales person will get back to you in 24 to 48 hours.

* Required Fields

Warranty

All products are protected by the Manufacturer’s warranty, unless otherwise specified. NCDS Canada guarantees that the products shipped to you are free of any defects; should your product be deemed defective we will happily exchange the item. If the item is no longer available, we will issue you a refund. Refurbished Products have a 30 day limited warranty, unless otherwise specified. For more information about product warranties, please see our Warranty Policy.